1. Tekla model
  2. CNC cut
  3. SAW weld
  4. UT & NDT
  5. Pre-assembly
Est. 2005

Engineering Excellence & Global Standards

Tekla-modelled, CNC-cut, SAW-welded and UT-verified structural steel for warehouses, industrial workshops and crane-served buildings — documented at every production stage.

CNC plasma and multi-head flame cutting line at the Xin Qiao fabrication plant
Fig. 01 — CNC profiling line Taian · CN
Facility
60,000 m²Taian, Shandong
Annual output
40,000 tper year
Governing codes
EN 1090-2 · AISC 360AWS D1.1
Detailing team
20+engineers
§ 01

Core Engineering Capabilities

Six uncompromising technical pillars that ensure structural integrity, precise site fit-up, and long-term durability in extreme climate conditions.

Tekla Structures 3D BIM model of a steel frame with clash detection 01

Tekla 3D BIM & Precision Detailing

Every project is modeled using Tekla Structures 3D BIM software. NC files exported directly to CNC cutting lines for zero-error assembly.

100% clash detection
High-precision CNC plasma and multi-head flame cutting equipment 02

High-Precision CNC Profiling

Multi-head CNC flame & plasma cutters achieve ±0.5mm cutting tolerances for steel plates up to 100mm thickness.

±0.5 mm cutting tolerance
Twin-arc gantry submerged arc welding line 03

Twin-Arc Gantry SAW Welding

Continuous submerged arc welding lines deliver deep penetration, backed by certified Level-II ultrasonic testing.

AWS D1.1 & EN 1090-2
Eight-wheel shot blasting and epoxy spray painting facility 04

SA 2.5 Shot Blasting & Coating

8-wheel pass-through shot blasting systems achieve SA 2.5 cleanliness, matched with controlled epoxy painting bays.

SA 2.5 surface tested
1:1 factory trial pre-assembly of a steel structure 05

1:1 Factory Trial Pre-Assembly

Complex spatial trusses, canopies, and multi-story frame joints undergo 1:1 yard pre-assembly to eliminate site delays.

Zero on-site rework
Ultrasonic non-destructive testing of full-penetration welds 06

Strict QA/QC & NDT Inspection

All raw steel sourced with MTC EN 10204 3.1. Full-penetration welds undergo Ultrasonic Testing (UT) by Level-II inspectors.

100% ultrasonic testing
§ 02

Technical Insights & Compliance Guides

In-depth technical guides answering complex questions regarding steel standards, anti-corrosion selection, and container shipping.

Pull-Off Adhesion Testing on Heavy Steel: Interpreting ISO 4624 Failure Modes Beyond Raw MPa
Coating QA/QC

Pull-Off Adhesion Testing on Heavy Steel: Interpreting ISO 4624 Failure Modes Beyond Raw MPa

Master ISO 4624 & ASTM D4541 pull-off adhesion testing on heavy structural steel. Analyze coating failure modes, dew point delta rules, and eliminate misleading MPa inspection data.

Read guide
Portal Frame Cost Optimization: Structural Engineering Guide
PEB Value Engineering

Portal Frame Cost Optimization: Structural Engineering Guide

Cut portal frame steel building costs by 15–30%. Master bay spacing, tapered built-up rafters, Z-purlin lap joints, and export logistics.

Read guide
Why Portal Frames Require Bracing: Mechanics, Detailing & Forensic Analysis
Structural Stability

Why Portal Frames Require Bracing: Mechanics, Detailing & Forensic Analysis

How vertical column bracing, roof horizontal diaphragms, and rigid tie struts eliminate out-of-plane weak-axis buckling and prevent progressive PEB collapse.

Read guide
Prefabricated Steel Structure Erection Sequence & Engineering Guide
Erection & Assembly

Prefabricated Steel Structure Erection Sequence & Engineering Guide

Step-by-step PEB erection workflow: anchor bolt tolerances, initial stable bay locking, crane runway alignment, wind post deflection detailing, and bolt torquing protocols.

Read guide
PEB Portal Frame Anchor Bolt Detailing: AISC & ACI Standards
Structural Engineering

PEB Portal Frame Anchor Bolt Detailing: AISC & ACI Standards

Engineering guide to PEB portal frame anchor bolt detailing: AISC DG1 base fixity, ASTM F1554 rods, ACI 318-19 breakout, and OSHA column stability rules.

Read guide
Clear-Span Prefab Steel Warehouse: Limits, Tonnage & Cost
Structural Engineering

Clear-Span Prefab Steel Warehouse: Limits, Tonnage & Cost

Master clear-span prefab steel warehouse design: AISC 360-22 limits, steel tonnage scaling (60-250+ ft), base thrust mechanics, and capex optimization.

Read guide
Optimized 40HQ Container Loading for Prefab Steel Buildings: Custom Dunnage, Bundling, and Volume Maximization
Structural Logistics

Optimized 40HQ Container Loading for Prefab Steel Buildings: Custom Dunnage, Bundling, and Volume Maximization

Master 40HQ container loading for prefab steel: alternating-taper rafter nesting, ISPM-15 dunnage, purlin bundling, and CTU Code dynamic load securing.

Read guide
Prefab Multi-Storey Steel Schools & Hospitals: Seismic Safety
Structural Engineering

Prefab Multi-Storey Steel Schools & Hospitals: Seismic Safety

Engineered prefabricated steel framing for schools and hospitals: cut seismic base shear by 45%, meet ASCE 7-22 drift limits, and accelerate turnkey delivery.

Read guide
§ 03

International Structural Code Compliance

One fabrication line, four code systems. Drawings, welding procedures and coating records are issued against the governing standard of the destination market.

Standard region Design & welding code Steel grade equivalent Galvanizing / coating code
Chinese codeGB GB 50205-2020 / GB 50017 Q235B / Q355B / Q355D GB/T 13912
European standardEN EN 1090-2 (EXC2 & EXC3) / EN 1993 S235JR / S355JR / S355J2 EN ISO 1461 / ISO 12944
American standardASTM / AISC AISC 360 / AWS D1.1 ASTM A36 / A572 Grade 50 ASTM A123 / SSPC surface prep
Australian standardAS / NZS AS 4100 / AS/NZS 1554.1 Grade 250 / Grade 350 / Grade 350L15 AS/NZS 4680

Have structural drawings or need a technical evaluation?

Upload your DWG or Tekla IFC files today. Our senior structural engineers will perform a 3D clash review and provide a detailed BOQ within 24 hours.

Input
DWG · Tekla IFC
Deliverable
BOQ + 3D clash review
Turnaround
Within 24 hours
Confidentiality
NDA on request